How Extremes works, and how well it holds up.
How Extremes works, for an engineer, actuary or reviewer deciding whether to rely on it: the data and licences, the models, the climate link, how each output is computed, the tests and the limits. The technical note, with every equation, prior and parameter for your file, is available on request, and comes with the Site Report, Portfolio and Pro. Fits built 2026-11-12.
Data and licences
| Peril | Data used | Period | Licence and attribution |
|---|---|---|---|
| Rain, wind, heat | ECCC daily climate data: London International Airport (6144475, 1940-2017), London A (6144473, 2012 on) and London CS (6144478, 2002 on), joined by date in that order of preference | 1940 to 2026 | Data Source: Environment and Climate Change Canada. Used under the ECCC Data Servers End-use Licence (eccc-msc.github.io/open-data/licence) |
| Rain (liquid) and rain plus snowmelt | ECCC daily climate data at the region's 20 long records: precipitation, rain and snowfall where reported, maximum and minimum temperature, and snow on the ground | 1940 to 2025 | Data Source: Environment and Climate Change Canada. Used under the ECCC Data Servers End-use Licence (eccc-msc.github.io/open-data/licence) |
| Freezing rain | ECCC hourly weather at the six staffed airports that report it (London, Windsor, Sarnia, Kitchener-Waterloo, Mount Forest, Wiarton): every hour an observer reported freezing rain or freezing drizzle, with its temperature and wind, and the day's rain | 1953 on, each airport to its step down in reporting after automation (London to 2026) | Data Source: Environment and Climate Change Canada. Used under the ECCC Data Servers End-use Licence (eccc-msc.github.io/open-data/licence) |
| Water on the lot (pilot: London) | Ontario Digital Terrain Model (Lidar-Derived): the bare ground from the province's laser surveys, at 2 m | Surveys of 2016-18 and 2025 | Contains information licensed under the Open Government Licence – Ontario |
| Warming paths (named scenarios) | CanDCS-U6: 26 statistically downscaled CMIP6 models (the data behind ClimateData.ca), annual mean daily maximum temperature, by county | 1971-2000 to 2071-2100 | Data Source: Environment and Climate Change Canada and the Pacific Climate Impacts Consortium (CanDCS-U6; BCCAQv2, Cannon, Sobie and Murdock, 2015, onto NRCANmet, McKenney et al., 2011), under the ECCC Data Servers End-use Licence. The CMIP6 model output is subject to the CMIP6 Terms of Use (Eyring et al., 2016). We thank ClimateData.ca for providing climate information. |
| Hail | Integrated Canadian Hail Database (2005–2022), v1.0.0: Brunet, D. and Brimelow, J. (2023), Zenodo, doi:10.5281/zenodo.8015925 | 2005-2022 | CC BY 4.0 (creativecommons.org/licenses/by/4.0). Changed by Musemakweli: reports under 1 cm left out, reports re-counted around each site and corrected for unreported hail days. The creators do not endorse this use. |
| Short-duration rain | ECCC Engineering Climate Datasets, IDF v3.40: annual maxima for 5 minutes to 24 hours at Southern Ontario's short-duration rain gauges, and ECCC's published curves to compare against | Each gauge's record (15+ years) | Contains information licensed under the Open Government Licence – Canada (open.canada.ca/en/open-government-licence-canada). Environment and Climate Change Canada, Engineering Climate Datasets, IDF v3.40 (5 December 2025). |
| Wildfire | Canadian National Fire Database, fire points: fires of 10 ha or more in Ontario south of 46° N | Sizes 1995-2025; rates 1980-2009 | Contains information licensed under the Open Government Licence – Canada (open.canada.ca/en/open-government-licence-canada). Canadian Forest Service, Canadian National Fire Database – Agency Fire Data, Natural Resources Canada, Canadian Forest Service, Northern Forestry Centre, Edmonton, Alberta (cwfis.cfs.nrcan.gc.ca/ha/nfdb), accessed [date]. |
| Tornado | ECCC Canadian National Tornado Database: verified events, F1 and stronger | 1980-2009 | Contains information licensed under the Open Government Licence – Canada (open.canada.ca/en/open-government-licence-canada). Environment and Climate Change Canada, Canadian National Tornado Database: Verified Events (1980–2009). |
| Tornado (to add) | Northern Tornadoes Project, Western University: the newer, more complete record | 2017 on | Commercial use needs permission; requested |
No provider endorses Musemakweli or its use of the information. None of the open-government statements implies official status.
- Gusts. ECCC reports a gust only from 31 km/h, and some years record 0 on every day. Zeros count as missing. A year is used only with gusts on 150+ days across 10+ months, which leaves 38 years.
- Complete years. Annual maxima use complete years with at least 80% of days observed.
- Ontario fires before 1970 are sparse in the database, so the fire record starts in 1970.
- Fires and tornadoes near a site are few. Both are fitted to the region's records, and each site's own count (fires that could have reached it, tornadoes within 75 km) is shrunk toward the regional average, so a site with none on record is not set to zero.
The models
Reading a return level. A 1-in-T-year level is the value with a 1/T chance of being reached or passed in any given year: a 1-in-100 level is a 1% chance each year, not a once-a-century event. Each year is a fresh draw, so two such years can come back to back, and over 30 years the chance of at least one is about 26% (1 − 0.9930) before any warming.
Two standard families from extreme value statistics (Coles, 2001), fitted by Bayesian methods so every parameter's uncertainty reaches the ranges you see:
- Peaks over a threshold for daily rain, rain plus snowmelt, freezing rain, hail, wildfire and tornado: how often events above a threshold arrive, and how large their excesses run (a generalized Pareto distribution).
- Annual maxima for wind, heat, the warmest night and humidex: the year's largest value (a generalized extreme value distribution).
- Two water perils (since E0.8). Rain (liquid) is the day's rain alone: ECCC's recorded rain where the station reported it, and otherwise the day's precipitation split by its temperature, using a curve fitted to the days on which the stations reported both rain and snow. Rain plus snowmelt is the water reaching the ground in a day: that rain plus the melt from a simple degree-day snowpack (in the tradition of the HBV model; Bergström, 1976; Hock, 2003) that builds with each snowfall and melts on days above freezing, faster when rain falls on it, checked against each station's measured snow depth. Both use the daily rain model (peaks over 20 mm). Snowmelt adds late-winter and spring events, when frozen or saturated ground sends more water to drains and basements; the largest days are summer storms either way, so the two perils' 1-in-100 levels are close, and their costs are never added together.
- Freezing rain (since E0.8): the ice it builds up in one storm, as the thickness of glaze around a wire or branch. Each hour an observer reported freezing rain, the ice added is worked out from the rain rate and the wind with the simple freezing-rain accretion model of Jones (1998), the one behind North American ice-load maps, and the hours of one storm are added up. Storms with more than 2 mm of ice are fitted as the other event perils are.
- Short-duration rain (5 minutes to 24 hours): one annual-maximum model across every duration at each short-duration gauge (a duration-consistent GEV after Koutsoyiannis, Kozonis and Manetas, 1998), so the curves can't cross and each duration borrows strength from the others.
- Events that come together: how often the same storm brings damaging wind and hail, measured in the region's records, so one roof is counted once; rain falling on snow, and heat-warning spells, counted from the daily records.
- Prior knowledge steadies the tail where records are short (for rain, the geophysical shape prior of Martins and Stedinger, 2000, adapted to peaks over a threshold; Coles, 2001, ch. 9, sets out the Bayesian approach); hail sizes and tornado ratings are treated as the coarse intervals they are; local event rates are combined with size distributions from a wider area with the same climate; and hail reports are corrected for the chance a hail day goes unreported.
The equations, the priors and their values, the sampler and its convergence checks are in the technical note.
The climate link
Each peril has a sensitivity to local warming, stated as a range rather than a fixed number, and carried into every result. Since E0.6, the sensitivities for rain, heat, the warmest night and humidex are measured from Southwestern Ontario's long records rather than set by judgement, and tested on years the fits never saw. Two kinds of warming path are offered. The simple paths rise steadily over the design life from today's climate: moderate reaches about +1.5 °C locally by year 35, and high about +3.5 °C by year 70. The named scenarios follow the calendar: the local warming in each year under SSP2-4.5 (intermediate emissions) or SSP5-8.5 (very high emissions), for a life starting in a year you choose, so a life that starts in 2026 already carries the warming since today's climate (2000-2025). Each site follows its own county's path. A warm-models version of each follows the 90th percentile of the climate models' changes in each year instead of the median (not one model's path), as a stress test. For a reserve fund plan, use SSP2-4.5. Paid reports and the Portfolio disclosure tables also give the 2050s and 2080s. The fits use each record from 1940 on and are read as today's climate, so today's rain levels read roughly 2-3% low; the change over the life is not affected.
| Local warming from today's climate (2000-2025), Southwestern Ontario average (range across the 15 counties) | 2021-2050 | 2041-2070 | 2071-2100 |
|---|---|---|---|
| SSP2-4.5 | +1.1 °C (1.0 to 1.1) | +1.9 °C (1.9 to 2.0) | +2.6 °C (2.5 to 2.7) |
| SSP5-8.5 | +1.1 °C (1.1 to 1.1) | +2.5 °C (2.4 to 2.7) | +5.0 °C (4.8 to 5.1) |
| SSP2-4.5, warm models | +1.6 °C (1.5 to 1.6) | +2.5 °C (2.4 to 2.6) | +3.8 °C (3.6 to 4.1) |
| SSP5-8.5, warm models | +1.8 °C (1.7 to 1.8) | +3.5 °C (3.4 to 3.7) | +6.6 °C (6.4 to 6.9) |
Source: CanDCS-U6, the 26 statistically downscaled CMIP6 models behind ClimateData.ca (Environment and Climate Change Canada and the Pacific Climate Impacts Consortium; ECCC Data Servers End-use Licence; CMIP6 Terms of Use), for the annual mean daily maximum temperature (the measure the sensitivities are estimated against), averaged over each county's populated area: the change from 1971-2000 to 2021-2050, 2041-2070 and 2071-2100, joined by straight lines between period centres. The middle path is the median of the models' changes; the warm-models path is the 90th percentile. Each path's warming is counted from its own value for today's climate, so every path starts from the climate the fits describe. The ranges in the results hold the uncertainty in the fits and the sensitivities; choosing the warm-models path is how to see the spread between climate models. Before November 2026 the named scenarios used the City of Toronto's table of the same models; the county paths differ from it by about 0.1 to 0.4 °C.
| Peril | What changes with local warming |
|---|---|
| Rain (liquid) | The size of extreme daily rain, in line with the physics of a warmer atmosphere (the Clausius–Clapeyron rate of about 7% per °C; Trenberth et al., 2003) |
| Rain plus snowmelt | Heavier rain, but less snow left to melt and more winter precipitation falling as rain: measured by rerunning each long record in a warmer climate, so it rises a little more slowly than rain alone |
| Freezing rain | How often ice storms come and how much ice they bring: more in midwinter, less in late autumn and spring, with little net change expected in the south; a wide range, since the records are too short to measure it |
| Wind | The spread of annual maximum gusts (little expected change, with uncertainty) |
| Hail | How often hail days come, and how large the stones are |
| Heat | The hottest day of the year, at about half the rate of the average day, as the records show |
| Warmest night | The year's warmest night, also more slowly than the average day |
| Humidex | The year's highest humidex, a little faster than the hottest day |
| Wildfire | How often large fires start, and how large they grow |
The sensitivities and their ranges are in the technical note.
Decision outputs
Each output is computed for every posterior draw, and reported as the median with a 90% range.
- Return level: the level with a 1-in-T chance of being exceeded in a year, today and at the end of the design life.
- Design-life chance: the chance of at least one exceedance over the asset's life, as the climate warms year by year.
- Design-life level (Rootzén and Katz, 2013): the level with a stated chance, 10% by default, of at least one exceedance over the life.
- Design value check: how rare your design value is today and at the end of the life, and its chance over the life.
- Expected cost: the cost per damaging event times the expected number of damaging years. Rain and rain plus snowmelt describe the same storms, so where both carry a cost only the larger is counted.
- When the water comes (rain and rain plus snowmelt): how many days a year bring 20 mm or more at the nearest long record, and the share of them from December to April.
- Wildfire and tornado: the chance a fire or a tornado path reaches the site.
- In Reserve: how damaging hail and wind bring a component's replacement forward.
- Hail and tornado at one building: the sizes are those of events within 10 km; the chance a design value is exceeded and the expected cost are for the building itself (a tornado path crossing it, or hail falling on it: a swath reaches about a quarter of the 10 km area).
- Weather through the year (Site Report): for a construction schedule you choose, the days a month with 10 mm of rain or more, 5 cm of snow or more, a mean below 5 °C (cold-weather concreting), a low of −15 °C or colder, a high of 30 °C or more and gusts of 50 and 70 km/h or more, and the weather-lost days with their 1-in-10 count; and a water-and-cold screen: freeze-thaw days, deep cold, ice-dam conditions, heavy rain on snow cover, the deepest snow on the ground, and how often storms exceed a typical storm sewer's 1-in-5-year hour, today and at the end of the life. From Environment and Climate Change Canada's daily records at the three nearest of the 20 stations that hold each measure (weighted by distance), 1991-2025, using months with at least 80% of days recorded. This screen does not forecast river flows: the report names the conservation authorities that map the floodplain for the county. Freezing rain is not in the daily records.
- River and lake flooding at the building (Site Report): where the conservation authority's floodplain map is loaded, whether the site is inside it and how far it is from its edge; and, from the flood depths on the first floor that the owner takes from that map (the regulatory flood and any others), the damage at each flood with a depth-damage curve (by default the U.S. Army Corps of Engineers' generic curve for a one-storey home without a basement (USACE, 2000, Economic Guidance Memorandum 01-03), or the owner's own, for example from Natural Resources Canada's Federal Flood Damage Estimation Guidelines), the expected damage a year over the floods given, and the chance of a regulatory flood over the design life, from the regulatory return period itself. It uses today's flood maps and does not forecast how river flows change with warming.
- Water on the lot (Site Report; pilot: London): where the rain the sewers cannot carry collects on and around the site in a cloudburst, and how deep. From Ontario's laser survey of the bare ground at 2 m, the screen finds every hollow, what it holds, the ground that drains to it and where its overflow runs, using the priority-flood algorithm (Barnes, Lehman and Mulla, 2014) and a fill-and-spill screen after Balstrøm and Crawford (2018), adapted by Musemakweli. The storm is the site's own one-hour rain at 1 in 10, 25, 50 and 100 years; the sewers are taken to carry the 1-in-5-year hour (or the level you choose) and the rest fills the hollows, each spilling to the next. It gives a map, the depth at the site's point and the deepest within 25 m, and the hollows nearby with how much rain fills them.
- Storms at this site (Site Report, Portfolio and Pro): each morning, Environment and Climate Change Canada's latest daily records are set against the site's fits: the day's rain, largest gust, hottest temperature and warmest night at the nearest station reporting, with how rare each was (for example, about 1 in 12 years, likely 1 in 7 to 25) and the station's name and distance. Days at or beyond a level you choose (1 in 2, 5, 10 or 25 years) are logged and shown in the app; the account owner can turn on an email for them, which is off by default and carries a link that turns it off. The page also lists the largest days of rain and of rain plus snowmelt on record since 1991 at the nearest long record, with their rarity by today's fits; both tables print in the PDF report.
- Test an upgrade (Site Report): for up to three upgrades (a larger culvert, impact-rated roofing, a backwater valve), you give what each costs and what it changes: the level at which damage then starts, the cost of an event afterwards, or both. The page plays out 2,000 futures of the site's weather along the warming path you chose, with and without the upgrade, and gives the losses avoided with a range, the net of the upgrade's cost, the dollars avoided for each dollar spent, how many futures in 100 pay the upgrade back within the life, and the year by which half of them have. In today's dollars, discounted at a rate you set.
- A bad year across the register (Portfolio and Pro), and rain and wind across an insured book (Accumulation): the storm catalogue. Thousands of simulated years of rain and wind over all your sites at once, in which every site keeps exactly the distribution its Site Report gives and nearby sites have their bad years together, as the region's 20 long records do. It gives the total in an average year and in a 1-in-10, 25, 50, 100 and 250 year, the same if the sites were unrelated and if they all had their worst years together, which sites drive the worst years, and for the register the same years 2 °C warmer. Beside it, past storms on today's portfolio: every heavy-rain storm since 1940, as it fell at the weather station nearest each site, costed on the register or book as it is today, with the ten costliest, the average year and the worst year on record. And one rain storm at a time: the storms on record at your sites replayed in thousands of new years, the large ones rescaled with their real footprints kept, for the largest single storm's cost in a 1-in-10 to 1-in-250 year. In Accumulation, all perils together: the year's total and the largest single event across rain, wind, hail and tornado in one set of years.
- Sewer backup, calibrated to your claims (Portfolio and Pro): your own claims by loss date, set against each day's rain plus snowmelt at the nearest long record (the largest of the day and up to three days before, whichever lag fits best), with a level for each season and your policies in force, in a model that allows storms to bring claims in bunches (a negative binomial regression; Hilbe, 2011). It gives how much each extra 10 mm in a day multiplies the claims, checks of fitted against actual claims by band of water and by season, the expected claims a year per 1,000 policies today and with warming (each day's water scaled by the rain plus snowmelt link), and for your current book the claims and the worst day in a 1-in-50 and 1-in-100 year, in dollars if you give an average cost per claim. The ranges come from resampling whole storms (a block bootstrap with storms as the blocks; Künsch, 1989). The claims are used for the calculation and not stored.
- Your insurance (Site Report hand-off): with your deductibles (one for all perils, and one for wind and hail if different), each damaging event's cost is split into what you pay and what is claimed, and your claims history is set beside the claims the report expects.
- Asset-type measures (Portfolio): culverts and storm sewers can be assessed on short-duration rain at their time of concentration (5 minutes to 24 hours), from the same short-duration fit as the Site Report; rows can carry an asset ID, replacement cost and criticality (1 to 5), ranked by the chance over the life times criticality, and imported from CSV.
- Loss curves (Accumulation licence): 5,000 simulated years of hail swaths, downbursts and tornado paths landing anywhere across the book. Events of at least a given size start at each place's own rate spread over the footprint, so a building inside one sees its own rate; one posterior draw is used a year. The result is the largest event loss (OEP) and the year's total (AEP) at 1 in 10 to 1 in 500, net of deductibles.
- A run ID on every output: each site's figures carry one ID (for example EX-3F9A21C07B) made from the method version, the data build, the place and the number of draws, printed on the PDF, the CSVs, the register, the disclosure tables, the Pro appendix and the hand-off. The same ID means the same numbers; the account keeps a site's earlier IDs and when they changed. Professional use of the outputs is set out in the terms.
- Accumulation (licensed to insurers, brokers and MGAs): for a book of locations with insured values and deductibles, the insured value within a radius of each location, and realistic disaster scenarios for hail (a swath 5 km wide and 25 km long), a downburst or derecho (a disc of 15 km radius) and a tornado (a path 0.5 km wide and 15 km long, south-west to north-east), each at the 1-in-T event size of its centre and placed where it costs the book most, with each location's expected annual loss. Screening figures with illustrative damage curves, not a catastrophe model.
Neighbourhoods within London: the same regional model
The free London preview and every paid report use one method: the regional model below (E0.5). For a point in London, each posterior draw comes from the nearest long records (mostly the London airport record, with St. Thomas, Woodstock and Stratford nearby), shifted to the point by the regional field of station records, and the hail rate is re-counted from the hail days reported within 20 km. The preview runs that model in your browser on the London-area part of the data, so a London point gives the same numbers in the preview as in a paid report, to the last draw.
What it shows inside the city: differences of a few percent for the wettest day and a few tenths of a degree for the hottest day, smaller than the uncertainty in the fits themselves. Gauges are 10 km or more apart and none sits downtown, so the field cannot see the urban heat island or street-scale rain. Places are found offline from neighbourhood centres, landmarks and postal areas, all approximate; the paid report finds the exact address with NRCan's Geolocator.
Southwestern Ontario (E0.5 regional model)
The paid Site Report, Portfolio and Pro cover any point in 15 counties: Windsor-Essex, Chatham-Kent, Lambton, Middlesex, Elgin, Oxford, Norfolk, Haldimand, Brant, Waterloo, Wellington, Perth, Huron, Bruce and Grey.
- Long records (hubs). Twenty sites with long daily records, each fitted exactly as London is (rain peaks over 20 mm, annual maximum temperature and, at the seven airports that report them, annual maximum gusts; hail around each hub), from 1940 on. Where a station moved or changed instruments, its climate identifiers are joined day by day.
- The regional field. Every station with 15 or more complete years since 1940 gets a value on one scale: the log of its mean wettest day of the year, and its mean hottest day. A secondary station's value is its nearest hub's plus the difference over the years both recorded, so a wet decade can't pass for a wet place. A Gaussian process (kriging; Matheron, 1963; Rasmussen and Williams, 2006) through these values gives the field anywhere, with a smooth part, each place's own local effect, and the uncertainty of both.
- At a site. Each posterior draw comes from one of the nearest hubs (weights fall off 20 km beyond the nearest, which keeps the result smooth between hubs and pools the tails of neighbouring records) and is shifted to the site by the field's difference between the site and that hub, sampled with its uncertainty. The field's uncertainty is widened so that, leaving each station out in turn, 90% of stations fall inside their 90% interval.
- Wind comes from the three nearest airports with gust records, weighted by inverse squared distance and not shifted: gusts were not measured anywhere else. Hail uses the nearest hub's fit, with the rate scaled by the hail days reported within 20 km of the site against those near the hub, shrunk toward the regional average (a gamma–Poisson empirical-Bayes estimate, as in Clayton and Kaldor, 1987). Wildfire and tornado (E0.7) use the region's records, with the site's own count shrunk toward the regional average, as for hail. Short-duration rain (E0.7) comes from the nearest short-duration gauges, weighted by distance. The warmest night and humidex (E0.6) come from the three nearest long records that have them, weighted by inverse squared distance.
- Places. Addresses and postal codes are found with Natural Resources Canada's Geolocator on our server; if it doesn't answer, the offline list of official place names (Canadian Geographical Names Database) places a town at its centre, and every report says how its point was placed.
The free preview and paid reports agree. The London preview shows recorded results of this same model, for the airport and the city's neighbourhood centres. Pooling neighbouring long records reads a few percent higher for rare rain at London than the London airport record alone (about 107 mm against 101 mm for the 1-in-100-year day), with a similar range.
Why the rain map is nearly flat. Between places, the wettest day of the year differs by only about 4% (the field's spread), and most of the larger station-to-station differences you might see in raw records are sampling noise: a few decades of annual maxima can't tell a 5% wetter place from a wetter few years. The model says so rather than painting a confident pattern. Rare-rain differences between sites come mostly from the long records themselves and their tails, which is why each report names the records it used. Heat varies more (the lakes cool the shore), and the map shows it.
Limits. Old records mix gauge types and sites; joined identifiers can carry a step. The field resolves differences between places about 30 km apart for rain and 40 km for heat, not street by street; lake breezes and urban heat appear only as the local effect's uncertainty. Hail reports follow people.
An independent check. A regional frequency analysis (L-moments; Hosking and Wallis, 1997) of the wettest day at 78 stations finds the region close to homogeneous, picks the same family of distributions the model uses, and gives 1-in-100-year rain at the long records within a few percent of the regional model's.
From hazard to credit (E0.5-C, in the Showcase engines)
The same fitted hazard runs inside the Showcase engines (the CRE Engine, the EWST Engine and the Control Room), Musemakweli's independent credit-risk research, so the showcases and a site owner's report rest on one set of numbers. The Showcase is research for discussion, not a service to lenders, and Extremes is not sold to lenders. Nothing is re-fitted for the credit work and no language model touches the figures.
- One loan (CRE Engine and Control Room). For each peril, every posterior draw gives the full distribution of the year's largest event at the property's neighbourhood. Damage curves for the property type turn intensity into repair cost and months of lost rent on the part of the building the peril reaches, split into the insured and uninsured shares. Integrating over the distribution gives the expected annual weather cost. A Monte Carlo then plays out every year of the loan term at that year's warming, with insurance premiums creeping up as insured losses grow, and records how often weather alone pushes the loan's coverage below its covenant (or below 1.00x for a loan already short of it; a bridge loan below 1.00x is triggered instead by a year whose uninsured weather cost exceeds 10% of NOI).
- Into PD, LGD and expected loss. A share of weather-driven breaches is taken to end in default (20% by default, shown at 10% and 40%), which adds to the loan's PD; a default that follows damage recovers less because the collateral is damaged. The engine shows the add-on to expected loss with that range.
- A book (EWST Engine and the ICAAP file). A physical scenario is set from a return-period event (peril, return period, year and warming path, at the median or the prudent 95th percentile), with damage by collateral type. The share of the book the event reaches is measured where data exist: on the airport's wettest day of each year, 19% of the gauges within 40 km also record their own 1-in-2-year day (median 14%, 53 years); a hail day's reports touch about 0.5% of the region, so with reports missing a third of the swath about 2% is used; a wind storm is synoptic, so half the region is assumed.
- Hail at one building. Hail is fitted as the largest stone within 10 km on a hail day. A single building sees only the swath that crosses it, so for one property the rate of damaging hail days is scaled to about a quarter of the circle.
Limits: the damage curves are illustrative and should be replaced by an engineer's or an insurer's curves for a real building or book; river flooding, which can damage a larger share of value and is often uninsured, is not yet in Extremes; the footprints assume the book sits in the London region.
Validation
1. Are the ranges honest? A simulation study
200 synthetic records per peril, drawn from the London fit with London's real design (record length, event counts and pooling), each refitted. Target: 90% of 90% ranges contain the truth.
| Peril | Record | True 1-in-100 | 90% range contained it | Same, 1-in-25 | Median error | Typical range |
|---|---|---|---|---|---|---|
| Rain (liquid) | 86 years | 101.7 mm | 90% | 90% | +1.0% | ±15% |
| Wind | 38 years | 135.3 km/h | 95% | 93% | -0.1% | ±10% |
| Heat | 85 years | 37.7 °C | 93% | 91% | -0.1% | ±3% |
| Hail | 18 years | 4.8 cm | 93% | 91% | +3.9% | ±40% |
| Wildfire | 30 years | 16 ha | 91% | 100% | +5.2% | ±57% |
| Warm nights | 86 years | 25.7 °C | 89% | 89% | -0.7% | ±3% |
| Humidex | 74 years | 49.5 humidex | 90% | 90% | -1.2% | ±3% |
| Tornado | 30 years | 152.8 km/h | 98% | 100% | +0.1% | ±14% |
2. Does it forecast years it never saw?
Each peril was fitted on its early years and scored on the later ones. If the model is right, the later values' forecast probabilities (the probability integral transform, PIT; Dawid, 1984) average about 0.5, about 90% fall inside the 90% range, and the KS p-value is above 0.05.
| Check | Fit on → score on | Scored | Mean PIT | Inside 90% | KS p | Reading |
|---|---|---|---|---|---|---|
| Rain, annual maxima | 1941-1995 → 1996-2025 | 30 | 0.47 | 87% | 0.356 | Passes |
| Rain, with climate link | +0.84 °C observed | 30 | 0.45 | 87% | 0.172 | Passes with the link estimated from the long records (E0.6); was 0.057 with the 7% a °C prior |
| Rain (liquid), annual maxima | 1941-1995 → 1996-2025 | 30 | 0.46 | 83% | 0.408 | Passes (E0.8) |
| Rain (liquid), 16 long records pooled | 320 station-years | 320 | 0.48 | 89% | 0.212 | Passes; with the link the later years read a little low (mean PIT 0.46, KS p 0.009), the signal that keeps the rain link small; the records share storms, so the pooled test overstates its power |
| Rain plus snowmelt, annual maxima | 1941-1995 → 1996-2025 | 30 | 0.47 | 90% | 0.612 | Passes with the link (E0.8) |
| Rain plus snowmelt, 16 long records pooled | 320 station-years | 320 | 0.48 | 90% | 0.383 | Passes with the link |
| Freezing rain, the year's largest storm | London, to 1995 → 1996-2025 | 30 | 0.38 | 90% | 0.036 | Fails (KS p 0.036): the later years read low against the earlier fit; the peril is provisional |
| Freezing rain, 4 airports pooled | 72 station-years | 72 | 0.41 | 90% | 0.025 | Fails (KS p 0.025), with each airport's record already cut at its step down in reporting after automation: the later years read low. Provisional |
| Heat, annual maxima | 1941-1995 → 1996-2025 | 30 | 0.50 | 93% | 0.867 | Passes |
| Heat, with climate link | +0.84 °C observed | 30 | 0.43 | 93% | 0.254 | Passes with the link estimated from the long records (E0.6); was 0.020 with the 1.1 a °C prior |
| Warmest night, annual maxima | 1941-1995 → 1996-2025 | 30 | 0.58 | 87% | 0.068 | Passes |
| Warmest night, with climate link | +0.84 °C observed | 30 | 0.50 | 90% | 0.672 | Passes |
| Humidex, annual maxima | 1953-1995 → 1996-2025 | 30 | 0.58 | 93% | 0.011 | Fails without warming: humidex has risen |
| Humidex, with climate link | +0.84 °C observed | 30 | 0.51 | 87% | 0.215 | Passes with the link |
| Wind, annual maxima | 1962-1985 → 1986-2022 (14 usable years) | 14 | 0.31 | 86% | 0.004 | Later gusts lower: sensor and site changes, surface-wind stilling |
| Wind, with the 2001 record change | 1962-1985 → 1986-2022 | 14 | 0.35 | 86% | 0.049 | Better: about 6 km/h lower since the airports' automation, measured at the other airports; the 1986–1996 gusts were already lower |
| Hail sizes, within 100 km | 2005-2014 → 2015-2022 | 39 | 0.53 | 100% | 0.015 | Reports rose from 8 to 39 (forecast 2-13): reporting, not hail |
| Wildfire sizes, Southern Ontario (10 ha+) | 1970-1994 → 1995-2025 | 158 | 0.60 | 79% | <0.001 | Fails: fires since 1995 are larger than the earlier record predicts, so the sizes are fitted on 1995 on (the current regime) |
| Tornado counts, the region (F1+) | 1980-1994 → 1995-2009 | 50 (forecast 27–57) | – | – | – | Passes; the share rated F2+ fell from 43% to 22% (rating practice), and the model keeps 40%, the conservative side |
| Short-duration rain against ECCC's curves | 44 stations × 9 durations | 1-in-2 to 1-in-100 | – | – | – | Median difference -3.9% to +3.2% by duration; ECCC's value inside our 90% range in 89–96% of cases |
3. Against published values
| Rain, return period | Our daily rain (90% range) | × 1.13 for a 24-hour window | Our 24-hour rain, short-duration fit (90% range) | Environment Canada IDF, 24-hour, London airport |
|---|---|---|---|---|
| 1 in 2 years | 47 mm (45-51) | 53 mm | 50 mm (47-54) | 51.3 mm |
| 1 in 5 years | 61 mm (57-69) | 69 mm | 67 mm (62-73) | 66.8 mm |
| 1 in 10 years | 71 mm (65-82) | 81 mm | 79 mm (72-86) | 77.1 mm |
| 1 in 25 years | 85 mm (75-103) | 96 mm | 94 mm (85-105) | 90 mm |
| 1 in 50 years | 95 mm (82-120) | 108 mm | 106 mm (94-120) | 99.6 mm |
| 1 in 100 years | 106 mm (89-141) | 120 mm | 119 mm (103-136) | 109.2 mm |
| Wind, 1-in-50-year | Value |
|---|---|
| Our annual maximum gust | 130 km/h (122-143) |
| Building code (NBC 2015), London q1/50 = 0.47 kPa | 97 km/h hourly mean, about 136-146 km/h as a 3-second gust |
Our rain is calendar-day totals. Environment Canada's IDF uses the worst 24 hours, typically about 13% higher (the 1.13 factor of Hershfield, 1961, and Weiss, 1964), and with that factor the values agree within about 5%. London's published curves are discussed by Simonovic and Peck (2009). The code's wind value is an hourly mean pressure; converting it to a gust uses a typical open-terrain gust factor of 1.4 to 1.5 (Durst, 1960; Harper, Kepert and Ginger, 2010).
What changed in E0.8 (November 2026)
- Rain is now liquid rain. Snowfall used to be counted as rain on the day it fell. It is now left out, so rain is the water that falls as rain. The heaviest days are summer storms, so the levels change by a few percent at most, within their ranges.
- A new peril, rain plus snowmelt. The water reaching the ground in a day from rain and melting snow, from a snowpack checked against each station's measured snow depth. It brings about 4% to 35% more days of 20 mm or more than rain alone, most of them from December to April, and the most in the snowbelt of Grey, Bruce and Huron.
- Its own warming link, measured by rerunning each long record in a warmer climate: heavier rain, offset in part by less snow left to melt.
- Both water perils are tested on years they never saw (below): rain plus snowmelt passes at London and pooled over the 16 long records with enough years; Chatham and Mount Forest fail with the climate link.
- A new peril, freezing rain: the ice an ice storm leaves around wires and branches, from hourly observations at six airports while observers reported it (London 1953 on; the others until automation thinned the reports). A provisional peril: London's largest storms on record, in March 1972, March 1985 and April 2003, each left about 13 mm by this measure.
- Warming by county. The named scenarios now follow each county's own path from the downscaled climate models behind ClimateData.ca, in place of one table for the region, and each comes in a warm-models version (the 90th percentile of the 26 models' changes) as a stress test.
What changed in E0.7 (November 2026)
- Short-duration rain, 5 minutes to 24 hours. Fitted to Environment and Climate Change Canada's short-duration records across Southern Ontario, one model for every duration, and checked against ECCC's own published curves, which it matches closely. Reports now give the depths for pipes, roof drains and inlets, today and at the end of the design life.
- Tornado from Canadian data. ECCC's verified Canadian tornado record, with an allowance for the tornadoes it missed in the countryside, and each site's own count. It forecasts the later years it never saw.
- Wildfire for Southern Ontario. The Red Lake reference (a northern forest) is replaced by Southern Ontario's own fire record, counting fires that start nearby or are large enough to spread to the site.
- Events that come together. Wind and hail on one roof are counted once, using how often the same storm brings both; the building code check adds rain on snow and heat-warning spells.
- A regional frequency analysis as an independent check of the regional rain model, for daily and one-hour rain.
What changed in E0.6 (November 2026)
- Warming links measured, not assumed. Heat and rain now warm at the rates Southwestern Ontario's 20 long records support. The hottest day rises more slowly than before, and rare rain a little more slowly. Both pass the test on years they never saw, which they didn't in E0.5.
- Two new perils: the warmest night of the year, and humidex. They matter more than the hottest day for health and for buildings without cooling.
- A building code check in every report: the Ontario Building Code's climatic values for the nearest listed place, beside what the site's records and fits give: the July design temperature (the code's 30 °C for London, measured 30.1 °C), the 1-in-50 one-day rain and the hourly wind pressure.
- Hail reporting. Hail reports grew about fivefold after 2014 because more people report, not because there is more hail; rates are now expressed at today's reporting level, which roughly doubles them.
- Wind record change. Gusts at the region's airports read about 6 km/h lower since they were automated around 2001. The published levels stay on the conservative side, and the change is shown beside them.
- Threshold uncertainty for rain is now inside the ranges.
- Tornado was withdrawn until Canadian data was in hand: no placeholder figures appeared in any report. E0.7 restores it from Canadian data.
Limits
- Tornado data. ECCC's database ends in 2009 and missed many rural tornadoes; an allowance for the missed tornadoes is applied.
- Wind types. Thunderstorm and winter-storm winds are fitted together, in one distribution.
- Short-duration rain away from gauges. Short-duration gauges are sparser than daily ones; the change with warming is measured at one hour and on daily totals, and blended between them.
- Wildfire spread. Fires are treated as compact patches; wind-driven spread and fuel are not modelled, and fire reporting in Southern Ontario fell away after 2005.
- Events that come together. Wind with hail is measured on few storms; rain on snow and heat-warning spells are counts, not yet joint return periods.
- River flooding is from the authority's map. The flood screen uses the depths the owner enters from the conservation authority's map and a depth-damage curve; Musemakweli does not model river flows, and the authorities' floodplain maps are loaded only where their licences allow. The default curve is for the structure of a residential one-storey building without a basement; for a condominium, other multi-residential or non-residential building the screen shows costs only with the owner's own curve or the share of value on the ground floor. The regulatory flood is the 1-in-100-year flood, a larger stated return period, or a regional storm (Hazel or Timmins), which has no return period, so no chance over the life is shown for it unless one is given; the area the authority regulates is wider than the floodplain.
- The storm catalogue: yearly totals, and single storms for rain only. The yearly catalogue links each site's largest rain day and largest gust of the year with every other site's; it gives yearly totals and does not say which sites were hit on the same day. Single storms are simulated for rain and for wind, from the footprints on record at gauges up to 25 km from each site for rain and gust stations up to 40 km for wind; a site away from its gauge is given its own part, sized from the measured link, and scaling a footprint up assumes its shape holds at greater size. Wind's are rougher: about 40 stations measure gusts, several sites often share one, and in our test the storms made distant sites more alike than the yearly measurements do. The two are built separately and shown side by side: on a ten-town test the yearly totals agreed at 1 in 100 and 1 in 250 for rain and for wind, and differed by up to a fifth at 1 in 25 and 1 in 50 for rain. How places move together for rain is measured at every distance, from 171 weather stations (thousands of pairs, some under 5 km apart): strongly local, about 0.77 at 2 km, 0.36 at 30 km and 0.15 at 100 km. For wind it is measured between the 28 stations that record gusts: steady near 0.15 to 0.2 beyond 50 km, since wind storms are regional. It cannot be pinned down within a city (only three pairs of gust stations are under 20 km apart: the link at 5 km could be anywhere from 0.23 to 0.76), so results are shown with the local link fading over 5 and over 50 km. Past storms use the rain (or the gust) measured at the nearest station within 25 km (40 km for gusts), which can miss, or catch, a burst a site did not get, and are not adjusted to today's climate. Rain and wind are drawn independently of each other, which is measured: at the seven records with both, a year's largest rain day and largest gust show no link (−0.04, likely −0.13 to 0.06), and they fell within a day of each other in 3% of years. Hail and tornado are combined with them as unrelated, which is assumed; flood and the other perils are not in it. Not a catastrophe model: it has not been reviewed outside Musemakweli.
- Water on the lot is a terrain screen, not a flood model. It uses the bare ground only: buildings, sewers, catch basins and culverts are not in it. A hollow behind a road or rail embankment may in fact drain through a culvert (hollows deeper than 1 m are flagged for a check on site), all the rain beyond the sewers' share is taken to run off, and water is placed where it comes to rest, not followed along the streets over time. A basement can flood from a sewer with no water on the surface. It has not yet been checked against records of flooded streets. London only for now; rain is for today's climate.
- Storm reports are preliminary and measured nearby. They use the first daily records, which Environment and Climate Change Canada may revise, at the nearest station reporting (rain within 30 km, heat and warm nights within 40 km, gusts within 60 km). A station some kilometres away can miss, or catch, a burst the site did not get, gauges can fail in the worst storms, and a storm that runs past midnight is split over two days. Rain plus snowmelt, freezing rain, humidex, hail and tornado have no next-day records and are not reported. Beyond 1 in 500 years the fits cannot tell rarities apart. The record's rarities use today's fits, which include those storms.
- The upgrade tester compares; it does not recommend. The upgrade tester compares options on your own figures: what an upgrade changes (the new threshold, the cost of an event afterwards) is yours or your engineer's to supply, and the answer is only as good as those. It counts at most one repair a year, leaves out benefits beyond avoided repairs (lower premiums, less disruption), and upgrades against different perils are not additive when one storm brings both.
- Sewer backup follows daily totals. The hour-long bursts that surcharge a sewer are stood in for by the day's water, so the calibration holds while the sewers, the policy wording and the claims practice stay as they were over the claims period. One weather station stands for the whole area, in Southwestern Ontario only; claims are not split by postal area, and the accumulation across a portfolio is not modelled yet.
- Freezing rain is observed at six airports. A site draws on the nearest of them; the rate each hour is the day's rain (not snow or ice pellets) shared over its wet hours and capped at 4 mm an hour (most of these stations did not measure rain hour by hour), and the ice is the equivalent radial glaze on an exposed wire, with no concurrent wind load and no shedding or melting within a storm, so the direction of the bias is unknown. Each airport's record ends where reporting stepped down after automation (Windsor 2008, Sarnia 2010, Kitchener 2009, Mount Forest 1978, Wiarton 1998; London has no step). Provisional: there is no public code benchmark to check it against, and it fails the test on years it never saw (below).
- Snowmelt is a screening model. The snowpack is a simple temperature model checked against snow depth at the long records, not a model of the site's watershed: frozen ground, ice jams and river flooding are not modelled, and melt that builds over two or three days is counted day by day. In the snowbelt the snow record is matched less closely.
Exposure also matters. Airport gusts are not rooftop or downtown gusts. Suppression near towns is inside the fire record but not modelled. The building code's values take precedence for design, and a municipality's own rainfall curve governs where it prescribes one.
The technical note
Every equation, prior and parameter: the two model families and their fitting, the shape and reporting priors, the climate-link sensitivities and their ranges, the regional field and how a site borrows from its long records (with the table of all twenty), the short-duration rain model and its comparison with ECCC's curves, the regional frequency analysis, the joint events, and the wildfire and tornado records and geometry. Engineers, actuaries and reviewers can ask for it; subscribers open it here.
Or write to info@musemakweli.com with your name, firm and what you are reviewing.
Reproducibility
The free previews show recorded results of the engine for their example inputs; subscribers' results are computed on Musemakweli's servers in Canada from the values they set, with the same engine, and the engine is available to reviewers on request. The fits, the out-of-sample checks and the simulation study run from fixed seeds, so a rerun on the same data gives the same draws. The research behind the rain model is in the extreme-rainfall research note.
References
- Balstrøm, T. and Crawford, D. (2018). Arc-Malstrøm: a 1D hydrologic screening method for stormwater assessments based on geometric networks. Computers and Geosciences, 116, 64–73. doi:10.1016/j.cageo.2018.04.010
- Barnes, R., Lehman, C. and Mulla, D. (2014). Priority-flood: an optimal depression-filling and watershed-labeling algorithm for digital elevation models. Computers and Geosciences, 62, 117–127. doi:10.1016/j.cageo.2013.04.024
- Bergström, S. (1976). Development and application of a conceptual runoff model for Scandinavian catchments. SMHI Report RHO 7.
- Clayton, D. and Kaldor, J. (1987). Empirical Bayes estimates of age-standardized relative risks for use in disease mapping. Biometrics, 43(3), 671–681.
- Coles, S. (2001). An Introduction to Statistical Modeling of Extreme Values. Springer.
- Dawid, A.P. (1984). Statistical theory: the prequential approach. Journal of the Royal Statistical Society A, 147(2), 278–292.
- Durst, C.S. (1960). Wind speeds over short periods of time. Meteorological Magazine, 89, 181–186.
- Gneiting, T., Balabdaoui, F. and Raftery, A.E. (2007). Probabilistic forecasts, calibration and sharpness. Journal of the Royal Statistical Society B, 69(2), 243–268.
- Harper, B.A., Kepert, J.D. and Ginger, J.D. (2010). Guidelines for Converting between Various Wind Averaging Periods in Tropical Cyclone Conditions. WMO/TD-No. 1555.
- Hershfield, D.M. (1961). Rainfall Frequency Atlas of the United States. Technical Paper 40, U.S. Weather Bureau.
- Hilbe, J.M. (2011). Negative Binomial Regression, 2nd edition. Cambridge University Press.
- Hock, R. (2003). Temperature index melt modelling in mountain areas. Journal of Hydrology, 282, 104–115.
- Hosking, J.R.M. and Wallis, J.R. (1997). Regional Frequency Analysis: An Approach Based on L-Moments. Cambridge University Press.
- Jones, K.F. (1998). A simple model for freezing rain ice loads. Atmospheric Research, 46(1–2), 87–97.
- Koutsoyiannis, D., Kozonis, D. and Manetas, A. (1998). A mathematical framework for studying rainfall intensity-duration-frequency relationships. Journal of Hydrology, 206(1–2), 118–135.
- Künsch, H.R. (1989). The jackknife and the bootstrap for general stationary observations. Annals of Statistics, 17(3), 1217–1241.
- Martins, E.S. and Stedinger, J.R. (2000). Generalized maximum-likelihood generalized extreme-value quantile estimators for hydrologic data. Water Resources Research, 36(3), 737–744.
- Matheron, G. (1963). Principles of geostatistics. Economic Geology, 58(8), 1246–1266.
- Pickands, J. (1975). Statistical inference using extreme order statistics. Annals of Statistics, 3(1), 119–131.
- Rasmussen, C.E. and Williams, C.K.I. (2006). Gaussian Processes for Machine Learning. MIT Press.
- Rootzén, H. and Katz, R.W. (2013). Design life level: quantifying risk in a changing climate. Water Resources Research, 49(9), 5964–5972.
- Simonovic, S.P. and Peck, A. (2009). Updated Rainfall Intensity Duration Frequency Curves for the City of London under the Changing Climate. Water Resources Research Report 065, Western University.
- Trenberth, K.E., Dai, A., Rasmussen, R.M. and Parsons, D.B. (2003). The changing character of precipitation. Bulletin of the American Meteorological Society, 84(9), 1205–1217.
- U.S. Army Corps of Engineers (2000). Economic Guidance Memorandum 01-03: Generic Depth-Damage Relationships, 4 December 2000.
- Weiss, L.L. (1964). Ratio of true to fixed-interval maximum rainfall. Journal of the Hydraulics Division, ASCE, 90(HY1), 77–82.
Data credits are in Data and licences above and on the Sources page.
Decision support: not engineering, legal, insurance or investment advice.